Tensile - Charpy Impact - Jominy Specimen Sizes

 
Tensile Specimens Minimum Sample Requirements.
.500" Headed Tensile Specimen 6" long x 7/8" Diameter
.500" Threaded Tensile Specimen 5 1/2" long x 3/4" Diameter
.350" Headed Tensile Specimen 5" long x 5/8" Diameter
.350" Threaded Tensile Specimen 4 1/2" long x 5/8" Diameter
.250" Headed Tensile Specimen 3 1/2" long x 1/2" Diameter
.250" Threaded Tensile Specimen 3" long x 1/2" Diameter
.160" Threaded Tensile Specimen 1-1/2" long x 3/8" Diameter
 
Charpy Impact Specimens Minimum Sample Requirements.
Full Sample Specimen 1/2" x 1/2" thick x 2.065" long (10mm x 10mm)
3/4 Size Specimen 1/2" x .336" thick x 2.065" long (10mm x 7.5mm)
2/3 Size Specimen 1/2" x .303" thick x 2.065" long (10mm x 6.7mm)
1/2 Size Specimen 1/2" x ..237" thick x 2.065" long (10mm x 5mm)
1/3 Size Specimen 1/2" x .171" thick x 2.065" long (10mm x 3.3mm)
1/4 Size Specimen 1/2" x .138" thick x 2.065" long (10mm x 2.5mm)
 
Jominy Specimens Minimum Sample Requirements
CNC Machined 5-1/2" long x 1-3/8" Diameter
Manual Machined Samples 4-1/2" long x 1-3/8" Diameter
 