Our Weld Testing Laboratory was requested to perform Charpy V-Notch Impact Testing, Corrosion Testing, Weld Ferrite Determination, Weld Microexamination and Vickers microhardness testing to document any evidence of detrimental weld related conditions.
Photo 4: Mag: 500X; Etchant: Beraha Reagent
Location: HAZ of Base A at Root
Photo 6: Mag: 500X; Etchant: Electrolytic NaOH
Location: Base A at Mid-Thickness
TEST RESULTS
Vicker’s Microhardness Testing
Indentation
HVN-1kg
1
256
2
262
3
278
4
284
5
290
6
274
7
279
8
279
9
288
10
278
11
281
12
279
13
276
14
288
15
278
16
272
17
309
18
281
19
288
20
281
21
285
22
286
Indentation
HVN-1kg
23
303
24
288
25
321
26
266
27
278
28
266
29
268
30
258
31
278
32
257
33
286
34
285
35
279
36
278
37
279
38
297
39
278
40
297
41
311
42
293
43
293
44
297
* Testing performed in accordance with ASTM A923 – Method B & C, E92 and E562 using Clemex Vision Analysis system.
Macro-Examination
The macro-examination revealed complete fusion between the weld and the base metal as well as between individual weld passes, however weld slag inclusions and a weld underfill condition was observed on both sides of the weld root (see Photos 8 - 10).
Photo 8: Weld rofile Etchant: Hot HCl solution
Photo 9: Mag: 50X; Etchant: Hot HCl solution
Weld underfill condition (denoted with red arrow on Photo 8)
Photo 10: Mag: 50X; Etchant: Hot HCl solution
Weld underfill condition (denoted with blue arrow on Photo 8)